Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. ddsancho

    Derivation of process conditions from valve CV

    Hi, Hope this page can help you. There are some explanations about Cv and Kv flow coefficents with online hydraulic formulas with several units as inputs. www.valvias.com/flow-coefficient.php Regards Daniel
  2. ddsancho

    Problems closing a Larner Johnson Valve

    Hi, We have a 60" Larner Johnson valve mounted in a 20 meters pipe from free discharge. Water flow (20m3/s). Head Pressure 6 bar. When can only open a 30% !! We think that the actuator can not win the vacuum that water flow generates outlet the valve. Outlet the valve there are some...
  3. ddsancho

    Vacuum fan vs Air temperature

    Finnally I could understand my problem. In my test the fan was controled at constant voltage, but not at constant speed, so the the flow was not constant, and then it is not possible to apply the formula: P1 / P2 = (T1+273) / (T2+273) Thanks all for your dedicated time, Daniel
  4. ddsancho

    Vacuum leakage?

    I don't know if smoke could contaminate your system, but sometimes I test with incense to find out vacuum leakage.
  5. ddsancho

    Air - Orifice coefficient

    Thanks Eltron, The information you gave me is good but I am looking for hole flow coefficients at low vacuum pressure: 0 - 0.3 psig 0 - 1 inchH2O 0 - 200 mmH2O
  6. ddsancho

    Air - Orifice coefficient

    Hello, In my machine, atmosphere air goes into my vacuum system through some holes. Trying to apply the following formula, I would like to know where I can find the K coefficient. h = K * Q2 h: pressure drop Q: flow K: Constant flow The orice is 2 mm diameter, in a 3 mm thikness wall...
  7. ddsancho

    Vacuum fan vs Air temperature

    I have been studying the vacuum pressure capacity of a fan at different room temperatures (15 to 45 C deg). As it was supposed, at higher room temperature I had less vacuum because the air has lower density. The corrector factor that I use to link pressure and temperature is...