Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SSS148 on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. ATHAN2

    Difference of Type 1 & Type 2 Rebars

    I just want to ask you guys, what is the difference between Type 1 and Type 2 Reinforcement Bars?
  2. ATHAN2

    Cracks on Basement Wall

    Thank you very much to all of you for giving me wonderful ideas. I can use it for my next project.
  3. ATHAN2

    Cracks on Basement Wall

    Dik, T13,T16 is referring to the size of rebars based on BS Code. "T" denotes high tensile reinforcing bars with the specified characteristic tensile strenght of 460 N/mm^2. 13,16,etc are diameter of rebars in mm. Yes, its a double face reinforcement with concrete cover of 40mm...
  4. ATHAN2

    Cracks on Basement Wall

    The building is a two level basement. It is a perimeter basement wall with the lenght of one side of 93 meters. Coarse Aggregate Size 20mm. The designer assume that the wall (free standing) will support the external horizontal forces (soil, water, etc.).
  5. ATHAN2

    Cracks on Basement Wall

    Our design mix per cubic meter are as follows: 40 N/mm^2 @ 28 days; waterproof concrete Cement (OPC) 430 kg. Water 167 liters Fine Aggregates 735 kg. Coarse Aggregates 1000 kg. Admixture (S'pruf B): 2.58-3.23 litre/m^3 Slump : 100 +/- 25mm Design of Basement Wall:(Based on BS Code) For...
  6. ATHAN2

    Cracks on Basement Wall

    I have been supervising two building projects with basement and I have noticed that cracks on the basement walls are always occurring. This problem always give us a headache because of the delays being incurred during rectification works. We are using PU Grout to sealed it off and prevent the...