  1. layloban

    epoxy grout on concrete foundation

    Hi, I have a question on the strength of epoxy grout on rotating equipment. The strength of the epoxy grout that we use on the rotating equipment is about 10000 psi and the concrete foundation is about 5000 psi. In this case, why does it need to use 10000 psi epoxy grout? If vibration is an...
  2. layloban

    Covert to PDF script

    Hi CadDraftee, I did figure it out and I know how to change the destination folder now. I use acrobat distiller to create PDFs. If you go to the settings>>Printers, go to properties of acrobat distiller, you will find a "Port" tab and from there you can create a new port with a user defined...
  3. layloban

    Gas Compressibility factor spreadsheet

    All, Thank you very much for your advice. I really appreciate it. Katmar, Is uconeer a unit convertion program? I can't find anything that is related to gas compressibility. Thanks again!
  4. layloban

    Gas Compressibility factor spreadsheet

    Hi, I'm working on a project to predict pressure drop in a pipe for various gases. One piece of information that I need is the compressibility factor for the working fluid. Does anybody have any suggestion on software or excel spreadsheet that I could use or purchase? Thanks in advance. Chan
  5. layloban

    Covert to PDF script

    Hi Lothar, I'm using AutoCAD 2004. I understand I need to plot to acrobat distiller. However, at the end of the process it will prompt you to enter the file name and/or location to save the pdf file. I'm trying to write a script to automate this but I do not know how to bypass this prompt...
  6. layloban

    Covert to PDF script

    Hi, Could anyone help me on a script to convert dwg file to pdf format? I have about 200+ dwg that I need to convert. I have acrobat distiller installed already. My problem is that I do not know how to write the script to specify the save command when the file dialog box comes up. I would...
  7. layloban

    Reference condition for Reciprocating Engine

    Hi, Does any one know what the typical performance reference condition for reciprocating engine is? I have seen engines that are referenced to ISO 3046/1. What is ISO 3046/1? Thanks in advance.
  8. layloban

    Flow rate calculation

    Hi, I have a question about flow rate calculation. The situation is that there is a 150# process drain with 1" diameter. We have been told to install a reducer to decrease the pipe diameter to 1/2" first before it goes into a drain tank. The reason is to reduce the pressure such...
  9. layloban

    DI water cooling tower

    I'm wondering if anyone knows what kind of chemicals are needed for a cooling tower (Assuming that the cooling tower is upgraded to handle corrsion problem) that uses DI water instead of raw water. What would the blowdown rate be? Thanks a lot!