There is a group in the University of Tulsa which has worked with this kind of separators for many years.
You may want to check some of their papers:
in the site: http://www.tustp.org/publications.asp
try "Compact Cyclonic Separator"
good luck
Jorge Robles
j.robles@cfertech.com
Thanks 25362,
I've decided to apply the following approach:
- Since I know that the air at the separator is 100% saturated, this also mean that the partial pressure of the steam (Pv) = Pstautarion a Separation Temp. Whit this I can estimate the molar fraction ratio's for the pseudo components...
Hello, for an experimental setup I need to connect a 6in pipe line to a 9 5/8” casing. I wonder if there is any kind of standard piece that I could use (or modify to be used) as a tee.
Thanks,
JR
I need to measure an air& steam stream coming out from a separator at 200 deg C and 600 psig, and to estimate their individual mass rates.
I think this could be done just measuring the volumetric flow rate, pressure, temperature and applying Dalton’s partial pressures law. I would prefer not to...
For this system you will have also to design a rod string, which has a maximum allowed Torque. A practice I recomend is to size the motor to handle the maximum operational torque (hydraulic and frictional torque at the pump + rod friction) but below the maximum value allowed by the rods.
In...