Hi jetmaker;
Thanks for your input, it is appreciated.
Unfortunately, I was not specific enough about my knife-edge holes. Material is .054" thick at low tolerance; head flushness can go to -.005; HiLok shear head for -5 is .041 max deep. That leaves theoretical min shank of .008, not a...
Thanks for the reply, bwain.
Testing would be ideal, but it would also take quite long - not the test itself but the red tape before it.
On the references, there is a graph in Niu (design), say page 232 or so, but it is fairly general in nature - and there is always a question how to quantify...
Hi there:
I hope that some of you guys might be able to direct me to some reference material on quantification of near knife-edge installation of HiLites, all with interference fit.
Structure has passed fatigue test with no cracks reported. Yet, without some quantitative analysis it is next to...