Thanks a lot to all of u. :)
Well, this query was to my own grooming. I am quite impressed by more than satisfactory answers of u people. In past few months (offcourse since i had explored this very useful site) i had checked numerous querries of my interest several times before they get...
Thanks hacksaw for reply, actually we have chemically cleaned five HX's in the annual overhaul (a month before) and found scale & sludge both on CW side (after one year service). So I am willing to get reference data which would be compared to quarterly sets. We have vendor's AS BUILT...
HI
Can anybody share with me the specific applications of Vertical Centrifugal Pumps with reference to TDH required, Capacity and fluid characteristics.
Greetings,
Chem98