There is a commercial unit for condensing water from humid air.
http://www.wataireindustries.com/
They even have residential units. They have quite a bit of information on their site.
How were the numbers of Mach 58 and -33202 psi pressure calculated? Bernoulli's equation would only be able to give you one of those values. You have to pick a point at the exit where you know the pressure or velocity and then you can use the equation to calculate the other. You can't use the...
If you have a separate outlet and inlet, you could use an altitude valve or float controlled valve at the tank. This valve would close as the tank fills. When the tank is full, the valve should close and the pump will dead head. A pressure sensor at the well could detect this condition and stop...
I'm looking for a chlorine contact tank that can be used under pressure. I have a project for three small water treatment systems. The sources are groundwater. I want to use the well pump to push the water through the treatment plant and into the distribution system. The sizes I'm looking for...