Dear all,
I need a water heating and cooling system to ramp up and ramp down temperature of a specimen. I have found that the Boe-therm Temp 95 can do the job (http://www.fleming.net.au/files/brochures_for_web/boe-therm_brochures/brochure_temp_95.pdf). However, I need to connect my control...
Hello IRstuff !
Here is more information:
The specimen is a concrete bar with dimension of 100 x 100 x 1000 (mm). The axial load on the specimen can be both tension and compression but this is a static load, therefore a gap in the thread will not cause serious error in control. However, small...
Hi brothers,
I need an electrical-mechanical linear actuator for control of a nearly static load. The head of actuator applies force to a concrete specimen through a steel spring which is much softer than the stiffness of the specimen. The target control is the displacement on the concrete...