Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. jasonmm

    Property Line Footing Problem

    I am working on some CMU houses that are going to be constructed with about 1" of separating between their "property line walls". The structures are totally separate except for measures taken to keep water from getting between the two walls. The builder would like to use a continuous footing...
  2. jasonmm

    Wood Rafter Design Using WFCM

    I use the Wood Frame Construction Manual (WFCM) as a design resource when designing residential houses. My question pertains to the rafter span tables. How do these tables account for wind? There are some span tables that include a ground snow load but none that include wind loads. Thanks...
  3. jasonmm

    Concrete Slab-On-Grade Control Joint Reinforcement

    I have always detailed my control joints for a slab-on-grade with the reinforcement running continuous through the joint. I show a (1/4)*slab thickness cut and the steel mesh or other reinforcement running continuous. Does anyone terminate there reinforcement at the joint? Why?
  4. jasonmm

    Concrete Reinforcement Anchorage to Steel Beam

    I am designing a residential structure with ICF walls. There is a 2nd floor ICF wall that does not have support below so I designed a cast-in-place beam to carry the wall. The builder would like to use a steel beam instead. What types of anchorage would be acceptable for the wall...
  5. jasonmm

    Concrete Cover w/ vapor barrier

    This will be a structural slab that is cast against the ground. This is a beachfront home so I am accounting for scour. All things considered, I think my best option will be to increase my slab debth in order to get the 3" cover. Thanks for all the input.
  6. jasonmm

    Concrete Cover w/ vapor barrier

    Can the required 3" of concrete cover be reduced for a slab that is cast against the ground if a vapor barrier is used?
  7. jasonmm

    Concrete Development Length for Hook

    Thanks for the ideas. I can make the slab bear on the 6" wide beam instead of framing into it. The opposite side will have to frame into a beam but it is 8" wide. I would have increased the beam size but the architect is set on 6". This was my first post and it is good to know that there is...
  8. jasonmm

    Concrete Development Length for Hook

    Hello, I have a job where I have a one-way-slab (8" deep) that needs to be supported by a 6" wide concrete arch beam. My top slab reinforcement is #4 bars at 12" o.c. Is there a way to obtain the reinforcement development in a 6" wide member or is there a type of connection that would be...
  9. jasonmm

    10 Story Condo Foundation Cost?

    The condo will be located in Florida.
  10. jasonmm

    10 Story Condo Foundation Cost?

    I have recieved the estimate for a foundation design of a 10-story concrete condo. The soil conditions are sand and it is an auger-cast pile foundation. My question really has to do with a general price per sq. ft. of building for the foundation. The cost estimate we have is running at...
Back
Top