Hi all
Doing some work for existing Claus Unit. Problems with catalyst powder are breaking electric resistances on reheaters (yes, they are electric) and clog liquid sulfur down valves on condensers.
Due to resistance breaking, temperature is to low on catalytic reactor and reaction does not...