Search results for query: *

  1. anilkk

    Sub marine pipeline

    We would be installing submarine pipelines at the water depths from 1400M to 2700M. Being deep waters, there would not be any concrete coating. I would like to know how to protect the anodes during laying of the pipeline as these anodes would be protruding outward and may damage during passing...
  2. anilkk

    Sub sea system

    We are installing subsea production system in the water depth of about 2700 meters. Would like to know the vendors for supplying proven pipeline connectors (Hydraulic with mechanical back-up) of 2500# class in the of sizes 24", 14" and 16". Regards, Anil
  3. anilkk

    Gaskets for A-60 fire rated doors

    Ed, Can you tell me the dtails and contact address (Fax/email) of Keramab in Temse, Belgium so that our client can contact ? Anil
  4. anilkk

    Gaskets for A-60 fire rated doors

    One of our clients wants to procure gaskets used for the existing A-60 fire rated doors installed on offshore process platforms. Gaskets provided presently have damaged and can not provide gas tight sealing to the accommodation and other safe area spaces. These gaskets are to be inserted in a...
  5. anilkk

    Star Delta Starters for AC Motors

    During expansion of our plant we are providing star delta starters for 75kw, 37kw and 15kw pumps. This is to reduce starting current of the pump motors. This would reduce starting torque as well but the reduced torque is adequate for the service. I would like to know the required rating of star...
  6. anilkk

    Electrical softwares

    Dear All, We intend to buy softwares required for carrying out electrical engineering calculations. I know of IPSA and Dapper being used by AMEC and Brown & Root for short circuit analysis and motor starting calculations. Please let me know what softwares are available and their uses. Regards...
  7. anilkk

    Genset capacity for RTG crane

    I am carrying out design appraisal of Rubber Tyre Gantry (RTG) crane. Manufacturer intends to provide a Genset with an engine of 397 KW and generator of 480 KW (600 KVA at 0.8 pf). Total load connected to genset is one hoist motor (1x185 KW), four gantry motors (4x30 KW), one trolley motor (30...
  8. anilkk

    Claculation of motor power as per FEM standard

    I would like to know if rotating and other inertias (GD^2) are not given then how to calculate electrical power required for acceleration. I am talking abour Container Gantry Cranes. I am an electrical engineer.