reverse rotation does not unscrew threaded shafts or impeller in vertical shaft pumps IF -underlined- it is due to reverse flow. the purpose of non-reverse ratchets is to prevent reverse rotation coming FROM THE DRIVER. (that would unscrew shaft or impellers).
the only problem i would expect...