Hi Vaslava , I did not machine any one hub , I was only looking for a way to draw it to make a device.
Tolerance was not a problem for my task.
I cut it by laser.
Pardal
Art and Clyde:
Thanks a lot for your invaluable help.
Please feel free to send me any sketch or drawing to my e-mail.
devitg@ciudad.com.ar
They will be wellcome.
With the best regards.
Gabriel(aka)Pardal
Pardal
Hola Art , gracias por tus concejos.
Could you giveme some fatcts about what do you didi in such circunstance , at Perú, just the initial kick .
Maybe the best diameter or if parallel coils are better to use.
As comparing with standard air conditioning system you can see , 3/8 finned pipe , and...
Quark, Art and Clyde:
Thanks for you answer .
Forget about the "damaged ss coil"
One self is slave of his words , and king of his silence.
I shall admit my guilt action.
Some time ago I read a post asking about the proper length of a coil to be used as a direct expansion in the same condition...
Hi Montemayor:
All my prior facts was , as I think, the fast way to calc by comparation.So as I had a chiller with the up specification , I was trying to copy it.
As I can see you can help me with the end task to do .
I need to calculate the such heat exchanger to the following data.
Chilled...
Hi Quark.
It will be a change to the same fluid , tap water
The ss coil it's damaged so I need to replace it with a cooper coil.I can not made a ss coil.
I will add some antifreeze and a cooper corrosion inhibitor.
The chiller is set now to 12 °C water leaving temperature.
I understand about...
How it can be calculated the equivalent lenght of a coil used on a chiller.
This are the facts.
Chiller capacity 35000 BTU or 10Kw at 20 °C
The evaporator is a stainless tube coil
tube diam 19.05 mm 3/4" 1.25 mm thick
Tube lenght 18.5 m 60 '
I intend to change it to cooper tube 12 mm...
Hi popsin , are your's 3dparts????
Could you send me some example?
If so, do to
devitg@ciudad.com.ar
Seem to be a hard to do task , maybe INVENTOR could do it.
Pardal
MortenA:
Yes , we only use steel pipe , new , so the friction factor could be asumed , and the temperature is the normal on a house or building.
Pardal
TD2K.
Maybe the 25362's paper is not at his personal library , but I have a Phisic Book whose author is A GANOT published in PARIS and MADRID in 1972 , with pictures, not photo ,of the aparatus presented at the 1867 UNIVERSAL EXPOSITION OR TRADE OF PARIS .
If I'm not wrong this was when the...
Here in my country the gas piping for low pressure is handled by the POOLE formula , for natural gas up to 200 mm water column.
The formula is as follow
D= ( F^2 * 2 * S* L / H )^1/5
where
D= DIAMETER [CM]
F= FLOW [M3/HOUR]
S= SPECIFIC WEIGHT [0.65 FOR NATURAL GAS]
L= LENGTH [M]
H= ALLOWED...