8x5 hose? Is that 8mm o.d. x 5mm i.d.?
-Yup
Nitric acid? What strength? This may limit your choices significantly.
-40 % nitric acid solution
Lastly, palladium is not a fluid - unless its powdered? You probably mean some kind of palladium solution, such as chloride or fluoride?
-Yup it...
I am from Australia and am having problems sourcing plastic check valves and three way valves which are suitable for 8 x 5 hose. I am using these components for a dosing system whereby the three way valve will allow me to divert flow from two different source tanks (each with a different pump)...
I haven't had experience with PDL drives but I have encountered capacitor failures on control cards from other drive systems. Check the ripple on the DC bus. Usually
a 13 % ripple suggests a supply phase loss and could result in capacitor failures. Also, check the circuitry if there is a...
We are currently planning to attach a supply hose to an existing pipeline through a three way valve (in combination with non-return valves to avoid cross-contamination). We purchased a solenoid metering pump with a capacity of 2 bars @ 32 l/h and connector size 12x9 to supply a 40% nitric acid...
It depends whether you want to run vector speed or vector torque control. 1 for the former and 2 for the latter. You can set the gains yourself in group 23 or you could do an autotune by entering 1 in parameter 2305. Make sure the motor load is connected for this autotune. For the ID run...