I'd like to stop the simulation when nodal tempeatures at a region reach a predefined value. I had a look at 6.6 documentation and have some idea as:
*EXTREME VALUE, HALT=YES
*EXTREME NODE VALUE, NSET= , TEMP MAX=800
However, documentation is not so obvious in this subject. Could you please...
Hi,
I'm new in steel business. What is the difference between steel grades and standards?
I'd also appreciate if you could recommend the best cross reference between standards of different countries.
Many thanks.
Johnhors,
My area of interface is far away from this region. You won't get a correct stress distribution at the interface as you pointed. What if my point of interest is far away and I have at least 5 mesh layers between this joint region and my point of interest.?
Thanks for your help.
Hi all,
I'd like to find a way to couple tetra10 and hexa20 elements in a region.
1- Is there a pre-processor where I can do this coupling, selecting e.g. the surfaces?
2- Is there a algorithm to write an equation between the middle uncoupled nodes of tetra10 and let's say corner nodes of...
I experience network problems and sometimes when license is checked for standard.exe, vendor deamon cannot be contacted and the analysis exits.
For a big model it means 6-7 hours of job submition to be lost.
Do you know how to run only standard.exe without running pre.exe from the beginning...