  1. Griseo

    Capacitor measurement

    I have some difficulties to intrepret the values I get when I try to measure the insulating resistance in a capacitor of about 600 nF / 1000V. Any one can suggest me the better instrument for that?
  2. Griseo

    Unknown gas monitor

    Colegues: finally I found a device called Hydrocal 1002 from the swiss manufacturer MTE Meter Test Equipment AG for gas-in-oil-analysis with transformer monitoring functions. So it is not only Hydran!
  3. Griseo

    Unknown gas monitor

    Thanks to both colleagues. This device is intended to monitor gas produced in transformer oil. Hydran monitor I know very well! My doubt is if my customer is confused but according to its size and name (!) he will have a good engineering team.
  4. Griseo

    Unknown gas monitor

    I would appreciate if a colleague could tell me what is a Hydrocal gas monitor that is specified by an US facility. I only find in the Web this name as a molding material!!! Manufacturer reference will be great! Thanks from somewhere in Europe!
  5. Griseo

    Gas monitoring equipment

    Many many thanks to all colegues.
  6. Griseo

    Gas monitoring equipment

    Thanks. Unfortunatly this is the only reference I have. I search in the Google and I got something not matching! This is specified for a Southafrican company.
  7. Griseo

    Gas monitoring equipment

    Any one knows the manufacturer of "Gas monitoring equipment Type AMS500"? Any help to find it would be welcome. Thanks in advance
  8. Griseo

    Unit-Substation Transformers Efficiency

    Referring to Cuky2000's reply I would like to desagree with the efficiency formula in the picture. According to my opinion and to some (at least!) litarature, in the denominator there is a fault! If the efficiency is calculated as per ANSI practice - i.e. the rated power is the output -, all...
  9. Griseo

    Transformer cooler design

    Hi As a transformer manufacturer engineer I can call your attention to two points: first, that a pump to work in an ONAN mode must be radial type (centrifugal are often used with pure ODAF heat exchangers!) to have low pressure drop when stopped, and second, you must have a head-vs-flow working...
  10. Griseo

    Transformer noise

    I thank to my collegues for these replays. I'm sorry if I was not clear, but I'm searching for noise level calculation or estimation and not noise reducing methods!
  11. Griseo

    Runin excel macros

    I woul like to run a macro in Excel automaticaly in the following way (as an example): If the value in cell A1 is "x" run macro1; if it is "y" run macro2. Any body know if this is possible?
  12. Griseo

    Transformer noise

    I'm interested in calculation or estimation of audible noise in large power transformers (>100MVA). Is any practical method known for that? Any book or paper about noise calculation? Thanks