It comes down to the selective properties of the catalyst. Normal operating range for the mixed oxide catalyst is 257 to 308 C. Diphenyl Oxide/Biphenyl Blend with an atmospheric boiling point of 257 C is used as the thermal fluid.
HCHO plants use shell and tube reactors with anywhere from...