  1. timmckee

    Weld repairs to A105 Flange

    Steam leaks on pipe flanges is a common problem at our facility. Often the leaks can only be addressed during an annual maintenance outage. Usually by that time the flange face has been "cut" by the steam. We have repaired these defects by mechanical removal (grinding, PT the excavation...
  2. timmckee

    ASME PCC-2

    Hi, I would like to use ASME PCC-2 as a repair guideline for B31.1 piping systems. However I cannot find a reference to it in B31.1. It is not listed as an adopted standard in my jusrisdiction (British Columbia, Canada). Does that mean I can't use it?
  3. timmckee

    PWHT Requirements for P-No. 4 Material

    Thank you for the help.
  4. timmckee

    PWHT Requirements for P-No. 4 Material

    What governs PWHT requirements for P-No. 4 Materials? We are replacing flanges and a section of pipe on a 10" diameter steam line. The pipe is Sch 40 (0.365" wall) A335 P11 (P-No. 4 material). The piping is Non Boiler External Piping B31.1. However our weld procedure states that any pipe...
  5. timmckee

    Trouble interpreting ASME Sec IX QW-200.4

    Trouble interpreting ASME Sec IX QW-200.4 I want to make sure I understand this paragraph properly. I have an approved WPS for GTAW of SS piping and a WPS for SMAW of SS piping. If I wanted to produce a SS weld with GTAW root and SMAW hot pass/fill and cap I can do so using a combination of...
  6. timmckee

    Weld Repair in HAZ

    I have a set of 10" WNRF 600# flanges on an superheated steam line (765 deg F service temp) that need to be replaced The existing pipe is A335 Gr. P1 Sch 40 (P No. 3, 1/2Mo, no Chrome). The flanges are A182 F11 (P No. 4, 1-1/4Cr, 1/2Mo). There was no PWHT on the original welds nor do we plan...
  7. timmckee

    B31.3 Allowable Porosity

    I found the answer to my question - after obtaining a version of B31.3 more current than my 1993 copy. Note 5 has been removed, surface porosity is not allowed.
  8. timmckee

    B31.3 Allowable Porosity

    I'm confused over the allowable surface porosity for girth welds in all fluid services. Table 341.3.2A states that the extent of imperfection allowed is zero, however it also refers to Note 5 (These imperfections are evaluated for welds less than or equal to 3/16" in nominal thickness). Does...
  9. timmckee

    Pressure Gauge for B31.1 Hydro Test

    I should have been more specific - we are installing Non Boiler External Piping manufactured to B31.1.
  10. timmckee

    Pressure Gauge for B31.1 Hydro Test

    I'm confused over the requirements for pressure gauges that are to be used for hydrotesting pressure piping manufactured to either B31.1 or B31.3. Neither B31.1 or B31.3 state any requirements for gauge calibration or gauge ranges (at least that I can find, maybe I'm wrong). Nor can I find...
  11. timmckee

    Welder Qualification

    Thanks for your responses, much appreciated.
  12. timmckee

    Welder Qualification

    But ER70S is a F6 material.
  13. timmckee

    Welder Qualification

    Why not? (Assuming Procedure 3 has a valid PQR) Procedure 2 qualifies him to weld any P1 thru P11 material using F6 filler with GTAW Procedure 1 qualifies him to weld any P1 thru P11 material using F4 filler with SMAW
  14. timmckee

    Welder Qualification

    If a welder is qualified to: Procedure 1 SMAW P1 to P1 E6010 root, E7018 fill and cap Procedure 2 GTAW P8 to P8 ER316L filler Would that automatically qualify him for Procedure 3 GTAW/SMAW P1 to P1 ER70S root, E7018 fill and cap
  15. timmckee

    API 653 Repiar of Caustic Tank

    We are replacing a manway insert on a 40 year old carbon steel API 650 storage tank. The tank has been used as a White Liquor (Caustic) Storage tank. I'm concerned the inner shell to insert weld will fail due to caustic embrittlement of the shell material. Any suggestions as how to avoid this?
  16. timmckee

    Work Table Leg Design

    The formulas in CAN/CSA-S16.1-M89 differentiate between bolted connections and machined or fitted parts with the latter formula being more conservative. You are also correct about the oversized hole, I planned on 1/16th of an inch diameter over the pin size. I just finished the calculation...
  17. timmckee

    Work Table Leg Design

    Thanks. I'm using the Handbook of Steel Construction (Canadian Institute of Steel Constrution).
  18. timmckee

    Work Table Leg Design

    Hi, I'm trying to design a work table for our shop using 4x4x1/2" and 5x5x3/8" HSS members for legs. The legs are to be adjustable in height with the smaller HSS "nesting" in the larger. The table height is to be adjusted using the nested HSS and inserting a pin through the two members. I...
  19. timmckee

    NDE for a FRP tank?

    I believe IR (Infra Red) Thermography has been used for FRP pipe and tank inspections. I don't know about detection of cracking but I think it provides good results when there is delamination. If your tank product is at ambient temperature you might not see much.
  20. timmckee

    ASME Safety Valve

    Hi Fred, To answer your first question, the "V" stamp is the Section I stamp for BOILER safety valves, so yes you can use it on any Sec I Boiler as long as it meets the needed pressure and capacity, which you said it does. Now for "HV" and "UV" stamped valves, that's a different story. They...