Good afternoon all:
I am in search of the Military shot penning spec.
MIL-13165
Does anyone know where i can get a copy of this?
Thanks guys
Bob
_innov8_
satchmo - thanks for the quick answer. i think i am just putting in too much thought here. i have done the endurance calculation using 0.5 * Sult, and then multiplied all my correction factors, notch sen, temp, reliability etc. with the endurance limit. and yes, it is much much lower. like...
how do you guys calculate fatigue limit? i have been told to use 0.5 or 0.4 of the ultimate tensile strength but ive also be shown to use 0.4 of the ultimate or 0.75 the yield strength, whichever is lowest. what do you guys think? and could you direct me to somewhere that says which method to...
i want to thank everyone for the input. this has been a tremendous help. i do know that this motor does not have a VFD, it is simply 575volt to a constant speed 460volt motor. since in fact this motor (to my knowledge) has not failed or even kicked out a fail safe, then it just isnt drawing a...
thank you so much for all the input. i feel much better when dealing with AC constant speed motors. Has anyone ever heard of Cowern's Papers?
Bob
_innov8_
Thanks Dan, that is a big help. i think we are going to advise the customer to let us size the motor and fan properly based on 575volts. sizing the fan and motor is no major task - but when the customer asked us some questions about this blower and told us what was on the nameplate, I couldn't...
Thanks so much everyone for all the information.
What happened here is the customer has a high pressure blower/fan (FRP) with a 5hp motor rated for 460volt (motor speed is 1750RPM and blower speed is 2256RPM). This will supply a CFM of 960 at 8". he has been running 575volts to it since 2001...
yes, the motor is not operating "properly". Obviously, many other factors change with the operation of 575volts in the 460volt motor. If it is a VFD, which i believe it is, would it be possible at all to run 575volt in the 460volt motor and expect a motor base speed increase? thanks for the...
Hello all, I am new here and this is my first post. I did search through the postings as best I could to find an answer to my question, but no luck. My question is: in a constant speed AC 3 phase, is the voltage & motor RPM proportional? For example: if I have a 460v motor operating at...