Hi,
I have calculated the water hammer effect, and I have 500 psi (delta P), more my normal operation at the inlet valve (550 psig), my pressure can increase to 950 psig in my worst case. Also, I have calculated my closing time and I got 7 sec.
(with Joukowski's equations).
If my...
Hi PAN,
-What is your required flow rate? in the future 1400 m³/hr
-How about the velocity in your line size 10" or 12" in other sections? @1400 m³/hr, we'll get about 17 and 25 ft/sec.
Anyway, I have called the manufacturer and he told me that the "extreme" velocity limit is about 50-60...
Hi everyone,
I'm looking to find the maximum velocity that I can have in a hose...Someone has an idea about that?
I have found that the maximum velocity for 8 inches hose is 15 meters/second, but I bet that for gasoline, the velocity must be lower...( presence of electrostatic charge...
Humm...I have already looked API2350, but I didn't find anything about the overflows...
However, I have took the Kindsvater-Carter equation...Do you think that is good way?
http://www.lmnoeng.com/Weirs/RectangularWeir.htm
Regards,
Ken
Hi everyone,
I'm looking to find the right API code to sizing overflows on crude tank.
Can you tell me if you know this code...
Thanks
Ken Bilodeau
Chemical Eng. Jr