  1. khanvessel

    Internal FBE coating on girth weld

    Hi there, I am working on an offshore project,sour crude and gas from the producing platform will be transferred to the onshore plant through a sub-sea pipeline network, theses pipeline need to be internally coated with FBE, one of the major issue which we faced on previous project is the...
  2. khanvessel

    Internal FBE coating on Girth weld

    Hi there, I am working on an offshore project,sour crude and gas from the producing platform will be transferred to the onshore plant through a sub-sea pipeline network, theses pipeline need to be internally coated with FBE, one of the major issue which we faced on previous project is the...
  3. khanvessel

    HI, I need to install a 26" flan

    Hi All, Thanks for all responses and SORRY I couldn't reply due to some personal reasons. My client do not want to install clamp type flange due to high H2S in the gas, I believe ASME VIII design would be a good option as per LittleInch, however will try to contact GC LOK and Vector. Thanks...
  4. khanvessel

    HI, I need to install a 26" flan

    HI, I need to install a 26" flange on piping system designed for 5860 psig. ASME 16.47 is limited to CL 900 only, is there any standard for flanges above 24" for CL 2500? Regards Vassel
  5. khanvessel

    Operating 380V equipment on 400V supply

    Thanks Parchie, Same is for other auxiliary items as well such as UV dryers PLC etc? Can I use an auto-transformer?
  6. khanvessel

    Operating 380V equipment on 400V supply

    Hi there, Is it safe to operate a 3 phase 380V,50Hz equipmment (including motor, UV dryers, PLC and some other auxiliary items) on 400V,50Hz supply? Similarly 220V,50Hz on 230V, 50Hz (single Ph)? Regards
  7. khanvessel

    Is simulated heat treatment required for A350 LF2 in sour service

    There is a concern raised from one the pressure vessel manufacturer, that the test coupon for the normalized material (A 350 FL2) shall undergo simulated heat treatment. As per my understanding, forgings are exempted from this requirement per section UG-11(a) and UCS-85 (e)(f) of ASME-VIII...
  8. khanvessel

    NACE MR0175 requirement for ASTM B61/62(Bronze Alloy)

    We need to purchase bronze valve for slops system, fluid is sour. Is it required for bronze valvs manufactured from ASTM B61/62 per MSS SP-72 to be NACE MR0175 compliant? Thanks in advance for help. Regards
  9. khanvessel

    Resistivity of Crude Oil

    Hi, Does any one knows the resistivity of medium or heavy crude oil in omh-cm? Thanks
  10. khanvessel

    4" Subsea Ball Valve Design Life

    Hi, One of our client is asking to supply a 4" subsea ball valve in MEG (Mono-Ethylene Glycol) service with a design life of 50 years. Is it possible to have a valve for this much life (gurantee would be an issue I believe). Thanks
  11. khanvessel

    Vessel Material for Disulfide Oil(DSO)/Dimethyl Disulfide (DMDS)

    Hi, A storage vessel on an offshore platform to store Disulfide (DSO)/Dimethyl Disulfide (DMDS) is required, stored material is highly corrosive and flammable. Can I use plain CS vessel or CS with Inconel 625 (or any other suitable material) cladding will be required? MSDS is attached for...
  12. khanvessel

    Vessel Material for Disulfide Oil(DSO)/Dimethyl Disulfide (DMDS)

    Hi, A storage vessel on an offshore platform to store Disulfide (DSO)/Dimethyl Disulfide (DMDS) is required, stored material is highly corrosive and flammable. Can I use plain CS vessel or CS with Inconel 625 (or any other suitable material) cladding will be required? MSDS is attached for...
  13. khanvessel

    Minimum temperature for SA-516-70N

    Than k for you help, Vassel
  14. khanvessel

    Minimum Temperature limit for SA-516-70N

    Thank you all for your expert advice, It is recommend in one of our clients spec that if MDMT is below -47 C, clad the vessel with UNS S31254 or use SA 203 Gr D or E with impact and HIC test. Temp range in ASME II Table A1 is upto -20 F only. Regards
  15. khanvessel

    Minimum Temperature limit for SA-516-70N

    Hi, I am working on a PV having MDMT -58 degree F in wet sour enviroment, is SA-516-70 N suitable for this application? What is the minimun temp limit for SA-516-70N and where to find? Regards
  16. khanvessel

    Minimum temperature for SA-516-70N

    Hi, I am working on a PV having MDMT -58 degree F in wet sour enviroment, is SA-516-70 N suitable for this application? What is the minimun temp limit for SA-516-70N and where to find? Regards
  17. khanvessel

    Thermal Conductivity of caustic Solution

    Hi Does anyone know the thermal conductivity of 50% caustic solution (Aqueous) Thanks
  18. khanvessel

    Caustic Solution

    Hi Does anyone know the thermal conductivity of 50% caustic solution (Aqueous) Thanks