ACI-05 App D uses the CCD method for anchor bolt embedment design. Anchors will small edge distances are penalized in strength making it nearly impossible to develop adequate uplift strength. ACI allows for the use of supplemental reinforcement to provide for additional strength but gives...
I am designing a below grade sump that is 37'-0" by 24'-0" in plan. The controlling wall height is 40'-0". I am analyzing the walls use plate bending theory to get some relief on moment and shear from cantilevered design. What is the concrete shear strength if I am using plate theory as the...