  1. ukzn

    re-commission of 11/6.6 kv transformer

    guys i have all what marmite said, and i am pondering about the same things that he is. it does have Bucholz and even explosion vent protection. but the transformer is out and i will inform you all of the findings " THINK BIG "
  2. ukzn

    re-commission of 11/6.6 kv transformer

    I need some help in determining whether or not to re-commission a transformer or not, has we are not 100% sure that the transformer had or had not seen a through fault. The transformer feeder did not trip but the incomer to that board did trip on Timed- earth fault(51G), no other protection on...
  3. ukzn

    Delta-delta versus Delta-Wye

    ok before you all go on. what does this transformer feed. if motors or even other transformers are feeding of this board then a Star secondary will not suit your situation. also consider the that by incorprating a Star secondary that you will have to re-config the Restricted Earth Fault...
  4. ukzn

    CT kneepoint

    the rating on the side of the CT is the Minimum value that you should obtain. It also should correspond with the formula to calculate Vkp= S/(Ns*ALF) " THINK BIG "
  5. ukzn

    Metrosil

    Hi there people, I’m a technician in the electrical commission field of protection, and have recently come with a device called the metrosil. I have tried various ways of getting how it works and the true operation. All methods tried have given me conflicting answers, can anyone give me a true...
  6. ukzn

    Protection grading

    i am a young technician, and have been put on a new project, but i have limited knowledge and experience in grading of substaions, feeders and transformers. Anyone who knows where i can get valuable information regardings this topic, please help.
  7. ukzn

    Tranaformer Differential

    i was just wondering if anyone can help me, by explaining the old Transf. Diff pricipal, using inter-posing CT's. i have not worked on such a system until now. i understand the protection with the new electronic relays but not when you introduce electro-mechanical relays, with iner-posing CT's.
  8. ukzn

    high voltage transformers

    thanks for the feed back guys.
  9. ukzn

    high voltage transformers

    Can someone please help. I would like to know, why most HV transformers are connected Star-Delta, either on the primary or on the secondary. Does it have to do with the fault levels, or not. Why not just connect it Star-Star.