  1. HTElectrical

    Non bearing interior wall detail > 12'

    I was wondering if someone was going to ask me that. I used my cad artist to draw the plans for this small TI. We are a general contractor also, but mainly due commercial electrical. Scope of work was only to close an opening in an existing demising wall, add restroom, 200A panel, and...
  2. HTElectrical

    Non bearing interior wall detail > 12'

    I just received an updated for the CLV NV building department stating that 20ga @ 24" o.c. is good up to 16'. I guess I will just change the drawings and give my customer a change order.
  3. HTElectrical

    Non bearing interior wall detail > 12'

    I checked on MarinoWare under Limiting Heights Tables (Composite) using a 3 5/8" member 358DWS25 5 PSF, L/120, and 24" O.C. it shows 13'9". I am missing something or will this pass? The city engineer said she was going to send over a new detail for walls over 12' and she sent the same detail...
  4. HTElectrical

    Non bearing interior wall detail > 12'

    Using 2003 IBC will a 13' tall interior non-bearing wall using the following material pass code? 1. Studs braced with 5/8 gyp board ea. side. 2. 25 ga 3 5/8 tract and stud. 3. Bracing @ 4'-0" O.C. staggered 3 5/8 25ga. The 2 walls are for a restroom addition and are attached to an existing...