Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: kaet
  • Order by date
  1. kaet

    Wet Well Influent Piping

    Just so you know, we've decided to use an inside drop into the wet well instead of an exterior drop. Thanks for the help! kaet
  2. kaet

    Transient Analysis Software

    Hi, I am trying to get input on the best water hammer software to purchase. I have found the other posts on this subject helpful, and thought others might have additional comments. I am debating between the following: AFT Impulse, and KY Pipe2000 Surge. I also am having a demo CD sent to...
  3. kaet

    Wet Well Influent Piping

    The wet well is going to be 15-20 ft deep (depends on survey which we are still waiting on). I have read that you don't want the influent to splash because it releases odors and causes entrained air into the pump suction. Thanks, kaet
  4. kaet

    Wet Well Influent Piping

    I am designing a wet well to meet current and future design flows (507 gpm, 910 gpm (2050). To prevent the influent piping from coming in at a very high elevation in the wet well to be above future design lead pump on elevation, I am considering using a drop manhole type inlet into the wet...