Thanks for your advices,
The fluid is a liquid mixture oxygen-nitrogen , this pressure vessel works into a cold box and he's protected
from ambient temperature by a special insulation.
I know i can used the same allowable stress until 150° for my material(according ASME DIV.II),but i don't want...
Hello everybody,
I have same problems to define the "right" design temperature for a new pressure vessel and i need help.
Operating temperature for this equipement is -190° C and the material is stainless steel, so i calculated this vessel with a design temperature at 20°C (because of test)...