Thanks, Guys,
I appreciate the suggestions you guys gave, they are very intereasting. Before making any conclusion, there are still some points to clarify:
1) To increase the inlet nozzle above the the liquid level(On the top of the tank)may solve the hammer problem. And the mist elimation is...
Dear Reena1957,
We have to swing the level from 20% to 80%,required by the process. there is a filter downstream, this filter works in batch by sequence, so this vacuum tank should buffer the liquid volume when the filtration stops.
In fact, there is a agitator in the vacuum tank, I don't know...
Hi, We are suffering from the vibration problem in our vacuum flashing tank. This tank is used to cool down the process fluid(water dissolving slight amount oraganics) to precipitate these solids. The inlet temperature is 100°C, inlet pressure is around 2 kg/cm2G, the flowrate is about 100 M3/H...