  1. bender36

    ACI 350 applicable ? Coating or not ?

    Hi, I have to design a concrete slab within a chemical plant. The slab is supporting vessels. In case of a leakage or disaster the liquid flows via slope to a short channel and then into a collecting pit. The liquid in the vessels is a solvent not attacking the concrete but that should not...
  2. bender36

    Subbase vs. Base (AASHTO Design Guide)

    Hi TDAA, hm, in general I fell that gravel or crushed stone is not that expensive. We have used ASTM D2940 for our final grading requirements for base and subbase course. O.K. I see a difference in the grading curves but does that lead to dramatic cost changes??? Martin
  3. bender36

    Subbase vs. Base (AASHTO Design Guide)

    Hi BigH, to make it clear: I had (still have) two issues that I do not entirely understand and I am surely not a Pavement Specialist: 1. The coefficient graphs in the AASHTO Guide: For all CBR values a granular subbase has a higher coefficient than a granular base - means a subbase...
  4. bender36

    Subbase vs. Base (AASHTO Design Guide)

    Hi Ron, thanks for your quick reply. I have plot a graph "Modulus vs. Layer coefficient" (see enclosed pdf) and obviously for each value the Sub-base has a higher coefficient !?!. Our Specification says that a granular base bayer shall have a minimum CBR of 60% and a granular subbase layer of...
  5. bender36

    Subbase vs. Base (AASHTO Design Guide)

    Dear Colleagues, I have a problem by understanding the following: The granular Subbase is supposed to be a lower quality material than the granular base. If I refer to the "1993 AASHTO Guide for Design of Pavement Structures" to obtain the layer coefficients, I get the following: a) Layer...
  6. bender36

    Shear strength acc. ACI 318R-02

    Hi, the shear strength provided by concret Vc is given in clause 11.3.1.1. The version which I have says: Vc=2*(sqrt(fc')/6*bw*d in the internet I found: Vc=sqrt(fc')/6*bw*d, but realted to the same code release. Same appwears for the limit of Vs (clause 11.5.6.9): Vs=8*sqrt(fc')*bw*d and...
  7. bender36

    development of positiv moment / anchorage of rfm in joints

    Thank you for your comments ! @ JAE: I have understood that I have to extend the bottom reinforcement anyhow in my support but question is fully developed or only 150mm? This is not clear! @ shin25: and what to do if there is only wind to be applied ? Thank you, MARTIN
  8. bender36

    development of positiv moment / anchorage of rfm in joints

    Dear colleagues, We are facing a problem in understanding and applying the ACI 318M-02 for our project. It is the first project we do acc. ACI. It would be very nice if somebody can help us: Problem: anchorage of reinforcement at joints / development of positive moment 12.11.1. (…) … such...
  9. bender36

    spiral reinforcement, bore pile ACI

    Hi together, the structural calculation of a bore pile (dia 1m, l=56m, seismic UBC 2A) gives us a certain amount of flexural reinforcement. According ACI318 (and frankly speaking I don´t understand the code 100% regarding that issue) the pitch of the spiral reinforcement (or ties) is limited by...
  10. bender36

    pitch of spiral reinforcement, bore pile

    Hi together, the structural calculation of a bore pile (dia 1m, l=56m, UBC 2A) gives us a certain amount of flexural reinforcement. According ACI318 (and frankly speaking I don´t understand the code 100% regarding that issue) the pitch of the spiral reinforcement (or ties) is limited by 7cm...
  11. bender36

    minimum reinforcement for piles

    Hallo together, for our current project (very weak soil!) we use bore piles with a lenght of 56m ! The structural calculation gives us a bending moment up to a depth of 30m. If we consider our piles as columns we have to provide a minimum reinforcement for the whole lenght acc. ACI. Is that...
  12. bender36

    Fire proofing, concrete beam, minimum dimensions

    Hi all, currently I am involved in a project in Egypt wich we design according american Codes and Standards. As I am not that familiar with the fire protection demands according american standards, I was searching for help in the web when I found by accident this references. I would be very...