  1. Ojit

    Blocked Outlet on a Vessel: Liquid Relief

    Apologies for your time. The dimensions and conditions of one of the Production Slug catcher (3x50%) are as follows: Vessel: Horinzontal Size: 4900mm ID x 19600mm T/T Design Press: 3500 kPag PSV Set Press: 3500 kPag HHLL: 4000mm Discharge Location: Hp Flare Header As explained earlier the...
  2. Ojit

    Blocked Outlet on a Vessel: Liquid Relief

    Thanks for the response. There is a control valve on the outlet vapour line and an ESD valve both on the outlet liquid line and on the feed line. I was guessing the feed ESD valve will trip after the ESD valve on the outlet liquid line trips. What do you think?
  3. Ojit

    Blocked Outlet on a Vessel: Liquid Relief

    Hi everyone. For a blocked outlet on a production slug catcher I need to determine what my releif load through the PSV when discharge lines are blocked. Do i size the PSV based on vapour rate or based on liquid rate? For a Blocked Outlet API states that (a) For Liquid, capacity is maximum...