I have to design a lintel 40 feet long. It will be supporting 12" solid cmu wall above so top flanges will be embed. Is it laterally supported or not. I think not.
Does any body has idea what is the ground snow load for NOrfolk City in New York state and also which buidling design code they follow. As per ASCE snow load is CS. So I am trying to contact the city engineer but no luck yet.
I have 3 feet deep pile cap. Due to lateral loads, I am placing rebars E.W. T&B. The Ast from analysis is less than minimum Ast = .0018 x b x h as Per ACI 318-05, Section 7.12, 10.5.4.
I am placing rebars each way both at top & bottom. Now I need this minimum Ast each way at top and bottom of...
Swivel63,
Appreciate your input but please read question carefully.
You answered
"Vu is factored shear force at the section considered"
Let me repeat my question here
"Vu is the VERTICAL shear from analysis?
Or we need to convert back the HORIZONTAL shear stress obtained from formula VQ/bI...
In ACI 318-05, Chapter 17, Vnh is the nominal horizontal shear strentgh. Vu is the vertical shear from analysis?
Or we need to convert back the shear stress obtained from formula VQ/bI multiply by bv x d .
JAE
For calcultaing Q we need the cross sectional area of either side of joint into the arm. What will be the arm? Is it from center of area on either side of joint into it's centroid to neutral axis. Also we assume neutral axis at geometric center of concrete beam with rebars?