John,
You can use the RedEye water-cut meter (Near Infra Red technology) to measure the BS&W in the liquid leg of the 2 phase separator. This meter has great accuracy in the higher water-cut range and works in the 0-100% water-cut range.
Now, you would also need a flow meter (turbine meter...
Thanks dhayes,
I really appreciate the quick calculation you have done. Just to add to your reply the "460" value in the aove calculation is to convert F to Rankins.
For our water-cut metering we really need to understand the GVF to understand the application and lot of times the operators...
Thanks for GVF & GLR/GOR units clarification, Sebasmagri & dhayes!!
It was interesting to know from Sebasmagri as to why do we need GOR/GLR ratios for reservoir engg. purposes treating gas & liquids separately.
Here is the information I have:
Liquid (oil+water) rate = 26500 bbls/d
Gas rate =...
Hi,
If some one can give me an insight into this will be very helpful.
Part 1: GVF = gas void fraction - what are the units for GVF (% or MMCF/BBls)....I am confused!!
Definition for GVF is (Gas volume)/(gas+oil+water); now the question is if GVF is defined in (%) what units do we take the...