Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Ipetu
  • Order by date
  1. Ipetu

    Step-by-step design guides or text books

    csd72, a2mfk, Thank you. I offer you my sincere love and friendship. Your respective posting's have motivated me to seek harder for what it is that I am after. One thing to remember is that your respective comments are not those that I have come to expect from Engineer's. Perhaps there are...
  2. Ipetu

    Step-by-step design guides or text books

    Kindly let me know if there are any design guides or text books that show step-by-step designs for a single storey residential building i.e. including all details from the foundation to the roof. I am also seeking design guides or text books for single storey commercials structures in steel...
  3. Ipetu

    Saddle type connection around concrete beam

    normm, The threaded bar is being drilled through after the concrete plinth is cast.
  4. Ipetu

    Saddle type connection around concrete beam

    Please see attached file for a sketch. The steel saddle plate type base plate has been used due the limited 200 mm (8") width of the concrete grade beam. Due to the limited width we are unable to use a four-bolt anchoring pattern to fasten the column base plate to the concrete. A couple of thru...
  5. Ipetu

    Opening in Structural slab

    Please see attached drawings and photo (multi-page PDF). Existing slab is 10" thick, rebar is #6, f'c = 3000 psi. Rebar pattern in this area seems to suggest that the slab is spanning mainly in the left to right direction. No special rebar is called up around the existing opening. Client wants...
  6. Ipetu

    Changes to Bridge Support Conditions

    Bridge EI, Proposal is to jack at bearing location, replace bearings, disable pins, make girders continuous at the hinges and then re-deck.
  7. Ipetu

    Changes to Bridge Support Conditions

    Forgot to mention...there are no seismic forces to be considered at this location.
  8. Ipetu

    Changes to Bridge Support Conditions

    Existing bridge has pin - hanger hinges at two locations. Due to their inherent weakness, the pin-hanger details are to be removed by making the girders continuous at the hinge locations. Furthermore, bearings adjacent to the hinge locations have to be changed from fixed to expansion to...
  9. Ipetu

    Overhead travelling cranes indoor

    Long loads (such as a long I-girder) are transported in a fabrication shop using two overhead traveling cranes. The two cranes travel on the same runway system. Each of the cranes have different remote controls. One obvious safety requirement would be that the rate of speed of each crane be the...
  10. Ipetu

    Grade beam modifications

    The code is CAN/CSA A23.3. I think it is similar to ACI 318.
  11. Ipetu

    Grade beam modifications

    dik, can you please expand on "not much you can do without overcutting the notch and epoxying embedded top bars at the notch" Is this to essentially replace the top bars (to be cutoff) with new top bars but now located below the notch?
  12. Ipetu

    Grade beam modifications

    hokie66, now that is outside the box thinking. I was trying to think outside the box but to no avail...I appreciate your suggestion.
  13. Ipetu

    Grade beam modifications

    A sketch of the existing and proposed grade beam is attached. The grade beam has to be notched to allow for barrier free access into the building. The slab on grade inside the building will also be dropped by...
  14. Ipetu

    Grade beam modifications

    This is an existing grade beam. Sorry I did not state this in my original post.
  15. Ipetu

    Grade beam modifications

    There is a 10" x 24" deep concrete grade beam reinforced with 2-30M (#9) bars top and bottom and 10M (#4 - 0.16 sq. in) stirrups at 24" o.c. The grade beam is supported on concrete piles (piers) at 20'-0" on center. Total length of grade beam is 100'-0". The total factored uniformly distributed...
  16. Ipetu

    Steel for Impact resistance

    A concrete wall in an industrial application needs to be protected against impact from machinery. Will 3/4" thick steel with a yield strength of 43.5 ksi (CSA G40.21) be satisfactory? Anyone with experience in this are please provide some feedback.
  17. Ipetu

    Column loaded on its web only

    JAE, The load is applied via a "shoe" for two jacks. The shoe is in the shape of an inverted U. The top of the inverted U bears on the column web. At the bottom of the legs of the U are stiffened seats for the jacks to sit on. One jack on each side of the column web.
  18. Ipetu

    Column loaded on its web only

    A W10x49 x 25' tall column is loaded concentrically but the load is applied only to the column web. The load is 40 kips unfactored. Does the column web need to be analyzed as a slender plate subject to axial load? Or, can it be assumed that the load will find its way into the entire cross...
  19. Ipetu

    Moment connections between beams of different depths

    Connectegr and others thanks for the helpful information. Connectegr what do you think of this solution (see attached file).http://files.engineering.com/getfile.aspx?folder=8534bbae-075d-4121-b138-fccbb05e25f8&file=2079_0001.pdf
Back
Top