Yes TCE has gotten a bad name but from those that improperly handled and disposed of it. I have many safe gaurds in place for dealing with thos types of issues.
TCE is widley used in many things beleive it or not read below.
TCE is a good heat transfer medium in the temperature range of -73°C to...
Let me correct on the 87% it is 85%. The pump is runnig at 85% efficiency which is about the maximium efficiency of this pump.
So the formula would go somthing like this
(1- %pump efficiency/100) * HP)*2500btu)=heat input
(1-85/100)*53.7)*2500)=20137.5 btu
Since i have two pumps doing the...
I am in the process of sizing refrigeration system that uses a closed chilled loop. I am circulating Trichloroethylene (TCE) @ -40 F. I am using two 60 HP 94.6% eff end suction cetrifugal PACO pumps in parallel. Each motor is using 53.7 bhp at load. I am 84.73% on my pump curve.
I know I need...