Thank you for the advise I have sourced a copy of UL-142 but as you noted it does not show specific details. I will need to keep searching as we have a high seismic requirement and I need assistance with the chair details to connect the two shells in some way.
I have been asked by my client to change our design for a 110m3 API650 (shop erected) heavy fuel oil tank from a single wall to a doubled walled construction due to a space restriction on site. My experience is with single wall tanks, could someone please advise where I may find the design...
Thanks 25362 I had seen that for the BP Transcal N, but obviously this detailed data is not available for 180 cSt HFO. From BigInch's data I get the viscosity at 50C of 205 SUS does any one have data that would give me the viscosity fron say 10 to 100 degree C. Would I assume that the Prandtl...
Thanks BigInch could you just confirm that this is for Specific Heat (based on 0.991 SG) should be 0.79 Btu/h/ft2/(Fº in)or should this read heat transfer coefficient, just checking my unit conversion to either W/m2.K or kJ/kg.K.
The oil is a 180 cSt No.6 Bunker oil, reference ISO 8217. The data sheet has some very broard temperatures and corresponding viscosities which is not of great help to me. The operating temperture range is 20 to 50 degrees celcius. I was hoping to locate data similar to that which I have for a...
I am currently checking the steam requirement for an existing suction heater, however I am having trouble finding the thermal properties of the oil ie specific heat capacity, heat transfer coefficient and maximum heat flux at the various temperatures. Does any one know where I can get this...