  1. Franko

    Odd Torsional Excitation - VSD Motor

    Sorry - should have said motor speed is 1/2 of inverter frequency. It is a 4-pole induction motor.
  2. Franko

    noise problem

    Sounds like you have two fans and one stack. Possible solution - could one fan rotate opposite direction to cancel sound waves? Many motors are reversible; one of the fans could possibly have blades reversed as well. It may be that the frequency is equal to one of the axial mode "organ pipe"...
  3. Franko

    Odd Torsional Excitation - VSD Motor

    Still under investigation - not proven but most likely due to electrical grid intermittent faults increasing component of 50 Hz grid frequency. Transient monitoring may still be done in the future.
  4. Franko

    Odd Torsional Excitation - VSD Motor

    Centrifugal compressor runs about 11000 rpm with motor near 1500 rpm. These large train components can't be mounted on rubber pads. I'm thinking they still may have missed some grounding issue to give the odd difference equation.
  5. Franko

    Odd Torsional Excitation - VSD Motor

    To Greg Locock's comment: What are some possible causes of doubling for rectification in a 4-pole motor that should be more symmetric than a 2-pole - I'm not a EE. Answers are below questions from Elecricpete: I have some questions (which is not to say I'll have answers): What is the machine...
  6. Franko

    Odd Torsional Excitation - VSD Motor

    A machinery train has vibration at the first torsional critical, but excited only near a certain speed. It is a "direct torque control" variable speed, 4-pole induction motor with 50 Hz utility grid frequency. The speed for high vibration events appears to be where: Difference between 2 times...
  7. Franko

    AC Permanent Magnet Motor Noise

    (fixed title) With a permanent magnet AC motor, for reducing noise, should the stator slots be completely filled? If so, is it best to use magnetic, non-magnetic, or semi-magnetic material? Also, are there service shops that can treat stators that have unfilled slots?
  8. Franko

    Step-up Transformer Frequency?

    Perhaps it could be an interaction - the frequency was shown to be constant with motor operating speed. It likely is a natural frequency of the electrical circuit. Has anyone ever seen one that low - i.e. indicative of a long time constant? See: quinn.mech.uakron.edu/me340/notes/me340sum.ps
  9. Franko

    Step-up Transformer Frequency?

    I believe it is isolated WYE connection and has a secondary grounded connection. However, harmonics are not the issue - they were low - but there was the odd low-frequency 8 to 9 Hz.
  10. Franko

    Step-up Transformer Frequency?

    It's an LCI drive with a DC-link converter - we are thinking that the step-up transformer is affecting the electric circuit. Has anyone found that the effective resonance frequency could be as low as 8-9 Hz? This is a large motor with about 10 MW operated on a stable grid.
  11. Franko

    Step-up Transformer Frequency?

    I posted this in Electric Power Eng'r forum - no response: We used a step-up voltage transformer for a test run with a variable-speed 60 Hz motor. There was an odd subsynchronous frequency near 9 Hz found in the converter output current signal. Could the frequency come from the step-up transformer?
  12. Franko

    Step-Up Transformer

    We used a step-up voltage transformer for a test run with a variable-speed 60 Hz motor. There was an odd subsynchronous frequency near 9 Hz found in the converter output current signal. Could the frequency come from the step-up transformer?
  13. Franko

    Pinion Gear Vibration At Bull Gear Frequency

    A speed increasing gear has a shaft displacement probe on the pinion. During operation, there is subsynchronous vibration on the pinion that changes with load. Frequencies are at one times and two times bull gear frequency, with much smaller amplitudes at other harmonics of bull gear frequency...
  14. Franko

    Displacement from accelerometer signal

    Why are you trying to do it yourself? There are great instruments out there; one example: http://www.endevco.com/main/news/2775b.php Filter Integrator Module 35818 provides a capability for single or double integration of the input vibration signal. Also contact: http://www.wilcoxon.com Be...
  15. Franko

    intermittent high 1x vibration on steam turbine

    My experience is that bearing temperature does not change much unless there are the two circumstances given above. If it's not an oil supply problem, the cause of the vibration would also have to simultaneously affect loading of the bearing. Also check oil drain sight glass before and after next...
  16. Franko

    intermittent high 1x vibration on steam turbine

    In your other thread you say that bearing temp. also increases. Normally that does not occur - you may have an oil supply problem. Try increasing oil pressure - and check for pressure drop from gauge to front bearing housing. If increase in temperature is actual metal temperature, there can be...
  17. Franko

    wahts the reason of a peak at 50Hz in the spectrum

    If you have an FFT, zoom in to be sure it is EXACTLY 50 Hz - if not it's a resonance - at least do a rap test. More vibration with defective bearing could be giving more broadband excitation to increase amplitude of 50 Hz. If it is exactly 50.0.... Hz, the coupling with mains frequency could...
  18. Franko

    Damping properties of materials

    unclesyd (Materials) Dec 4, 2003 Wtote: "I have an old grey-iron properties handbook that gives the relative vibration damping qualities of Gray Iron, Ductile (Nodular)Iron, and steel as pictorial graph. ........ ...........The damping capacity is little affected by either temperature...
  19. Franko

    Calculating noise level of a boiler blowdown

    Contact a blowoff silencer vendor for their calculation procedure: http://www.burgess-manning.com/ http://www.pulsco.com/ventlinesilencer.html
  20. Franko

    Looking for supplier of Acoustic Blankets for topside pipework

    Manil - if you use insulation and outer jacket, band the outer jacket to hold it. The issulation is the "spring" and the outer jacket is the mass that will short-circuit if it is tied to the pipe. Thus do not tie the outer jacket to the pipe. One supplier of removable blankets for odd...