Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. farhad2474

    potable water requirment

    Please tell me ,of course with reference standard , how much should be working capacity of water treatment unit for a industrial building with 15 person (just one shower at this station ) .thank you in advance
  2. farhad2474

    UL/FM approval

    Please somebody tell me , all equipments (valves ,pumps, pressure regulators )in the fire fighting pump station should have a UL/FM approval or not. thank you farhad
  3. farhad2474

    spiral-wound gaskets

    thank you so much unclesyd farhad
  4. farhad2474

    spiral-wound gaskets

    Please some body tells me ,it is necessary a spiral wound gasket have a inner ring. Our piping design pressure is 54 Bar and temp is 200 C. Thank you Farhad
  5. farhad2474

    valve body material for salty water

    Hi thank you very much plymouth tube
  6. farhad2474

    valve body material for salty water

    Hi Please tell me, We have salty water for our fire fighting network. The pressure is 130 psi and temperature is 30C. we have to kind of gate valve material body .one is Ductile iron and another is Cast Iron and both of them have epoxy coated (inside and outside) .just I want to know...
  7. farhad2474

    disc and seat material for globe valve

    thank you Mattc1234 Actually My question is ,can we use ASTM105+stellite disc in globe valve instead of %13 chrome steel +stellite disc because fluid (gas or liquid ) touch to the surface of the disc (stellite surface) farhad
  8. farhad2474

    disc and seat material for globe valve

    Hi Every body can tell me if globe valve disc and seat are 13% chrome steel. It can be stellite or it doesn’t need stellite .the service of valve for sweet gas. Thank you farhad
  9. farhad2474

    pipe support

    Sorry I did mistake. Actually in clamp catalogue write it down 30 ksi and I wrote by mistake kpi .so this is stress unit, and just tell me please how can I calculate the clamp can bear 43000 N forces when pipe is going up. Already we did stress analysis and with this force we are not going to...
  10. farhad2474

    pipe support

    Dear friend Thank you for your answer .this pipe is going to input of a compressor .we don’t like flange of the compressor get over stress .yes you are right .we can change piping arrangement to limit or reduce force, but it is not time to do this change for us . Would you please tell me...
  11. farhad2474

    pipe support

    Hi: Every body We have a 24 inch pipe, according to our stress analysis it coming up from its support at a point with a force 46303 N during operation .our contractor suggested to put a clamp that permissible force is 30Kips to keep it down . Can you tell me . is this right?.Thank for your...
  12. farhad2474

    NEMA Force Allowed on the flange

    thank for answering to my question i am going to use following Equation for allowable load on the flang of compressoer according to NEMA-23 Fx=50Dc Fy=125 Dc Fz=100 Dc Mx= 250Dc My= 125Dc Mz=125Dc Dc= (18+equivalent dimeter)/3 Am i right ? best regard farhad
  13. farhad2474

    NEMA Force Allowed on the flange

    hi ;DSB123 thank you for you answer . Really i am right. They wrote like this in the meeting with my company .I wasnt involve that time.so please tell me if you know a bout 10x NEMA . best regard farhad
  14. farhad2474

    NEMA Force Allowed on the flange

    Hi I recently involved with a compressor it has 16’’ flange at output. I am going to do stress analyze the pipe is connecting to this compressor. The vender’s catalogue mentioned that this compressor’s flange can outstand 10x NEMA forces . I would be appreciated if some body tell me what mean...
  15. farhad2474

    bolt and nut marterial for valve

    I will appreciate some body answer my question .i have stainless steel valve with body AISI 316SS.they use A193 B7 and A194 2H for bolt and nut in this valve .i think they are wrong. they should to use A193 B8M and A194 8M. Am I righ best regard farhad
  16. farhad2474

    External nozzle loads

    Dear Edward Please tell me how can I use allowable load tables (in API-610 ) in stress analyses .when a pipe connect to the pump. best regard farhad
  17. farhad2474

    External nozzle loads

    Actually, I am going to calculate pipe stress analyze for a pipe that connect to a pump so I start first node with flange so the program asked me following question for flange 1-flange type 2-flange weight 3-gasket diameter 4-allowable pressure. I don’t know what does the programs...
  18. farhad2474

    External nozzle loads

    Is any body Know how I can find external nozzle loads and moments for nozzle’s pump . I need those for stress analysing program. I found those in in API610 but there are in force unit(pound) I need stress(F/A)psi . thanks
  19. farhad2474

    flange rate#

    i have flange with material ASTM A694-F60. i am going to use for temperature 400 F and pressure 54bar . i couldnt find this material in ASME B 16.5 - can some body help me thank farhad
  20. farhad2474

    higher schedule pipe

    Thank you for your answer. But I looking for standard ,that tell me when should I use schedule higher .
Back
Top