  1. newmep

    Exhaust fan for restroom

    Hi, I need help finding litrature and advise on design of a central exhaust system from large public restrooms. Each facility has about 10 sanitary fixtures. 75 cfm per fixture is my target. Restroom is on first floor and exhaust must be thru roof on 3rd floor. Would the fan go on the roof or...
  2. newmep

    Thermostat with occupancy sensor

    On a project I want to use T-stat with occupancy sensor combo. Where can I look for tech data on them? Who are the players in this market? thanks,
  3. newmep

    Cooling load due to 100% outside air and no return air

    As you mentioned, the outside air has latent and sensible load components on the unit, and also the interior space could have latent and sensible load components. You have to add all loads of same type together to size the unit. hope this helps. Regards,
  4. newmep

    Chill water pipe insulation

    Can someone point me to a table for required insulation thickness around chill water supply and return pipes. Thanks,
  5. newmep

    Schrader Fittings w/ R-410a

    Make sure the fitting's o-ring seal is compatible chemically with the refrigerant material. The other thing is to watch for vibrations. A heavy switch on a simple schrader fitting will break-off quickly. Otherwise is it should be fine to do so.
  6. newmep

    NPT fittings in an AC system?

    A/C fittings should be SAE, type and preferrably backed up with an O-ring system. Vibration is severe in this application.
  7. newmep

    Static Pressure in air blowers

    I have a question along these same ideas. In pumps, there is an NPSH, required for pump to operate. Is there such a term and requirement for fans? Is there a minimum total head required on the fan inlet. Thanks,
  8. newmep

    200 amp Distribution panel in Boiler Room

    Can a 200 amp distribution panel be located in a boiler room? The room will not get hotter than max 120-deg F. thanks,
  9. newmep

    Chill water Coil Airflow

    Chris Conley: Is there a name for this max air velocity (max face velocity or max tube film velocity) or something technical like that. thanks,
  10. newmep

    Chill water Coil Airflow

    On a large old central AHU (30000 cfm), the maintenance wants to increase the airflow. I think that the chill water coil should have been designed for a specific airflow and we can not just increase the fan cfm. Please comment. Thanks
  11. newmep

    Elevator Shaft Cooling

    gepman, this is an exisitng building and owner just installed A/C unit on the roof of car, so they created the problem of overheating shaft. I have done the heat load and know how much 70-75 deg air I need to keep the shaft at about 90 deg. There is no top access to outside so we have to do a...
  12. newmep

    Elevator Shaft Cooling

    To cool off a warm elevator hoist way (3 story tall),we are going to introduce conditioned air at 75 deg. Is it better to extract air out from the top by an exhaust fan, or, force air in at the bottom with a fan? Should the piston effect of elevator travel be considered? Thanks,
  13. newmep

    Duct Heater aplication

    Thank you and merry christmass.
  14. newmep

    Duct Heater aplication

    Hi, What are some common situations when a duct heater is used and why. Doesn't the supply air provide required heating? Thanks,