Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: yoyoe
  • Order by date
  1. yoyoe

    Motor pulling higher then rated amps.

    Thanks for all the ideas. I have a little more info. The two motors are continuous duty motors with a service factor of 1.15. Each motor is direct connected to a hydraulic pump with a coupling. When the pumps are not pumping pressure they each draw about 24-26amps. When pumping high pressure...
  2. yoyoe

    Motor pulling higher then rated amps.

    I have a diecast machine with two 30hp three phase motors running 460 volts. Nameplate rating on them is 37.5 amps. Under load they each pull 40-43 amps. What I would like to know is this normal? I also have a problem with blowing the main fuses, LPJ 100 Sp. Amp meter says total amps through...

Part and Inventory Search

Back
Top