Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Forrest79
  • Order by date
  1. Forrest79

    AISI 4130 Temperature VS Pressure

    Hi friends, Can anybody help to find an AISI 4130 material properties, Temperature VS Pressure curve or table. I meet a problem, if I can use AISI 4130 in the condition of API 6A 10000 PSI and 300 degree C temperature. if not, what kind of material I should use. Sorry but I cannot find the...
  2. Forrest79

    B7 stud bolts manufacturing process

    Hey guys, recently we meet some problem about stud bolts and nuts. supplier provide B7 stud bolts, the bolts are thread rolled, then heat treated, I wonder during the quenching in Oil, may there be problems on the thread top, will there be some cracks, also during the heat treatment there must...
  3. Forrest79

    A694 Material Quenching process

    Dear heat treatment Specialist, I have a question about the quenching process of the A694 series material. 1. we have experience that for these kind of material, better quenching as soon as posible after moving from furnace to quenching pool. 2. one of our engineer did a test, when move the...
  4. Forrest79

    HIC and SSC TEST

    Hello Friends, We are working on NACE materials recently. I have a question about HIC the SSC test. Normally according to NACE MR0175, materials with controlled hardness, content of S and P, and yield strength according to MR0175 is acceptable for NACE application. Sometimes customer need HIC...
  5. Forrest79

    HIC TEST for Valves

    oh, both are very high I think. Maybe you can consider Cladding flange and valves. We are now supplying flanges to a Chinese Project named PuGuang, the H2S content also high 1? H2S range?12.31%~17.05%? 2? CO2 range?7.89%~10.53%? 3? Organic Sulfur: 340.6mg/m3 in Raw Gas Design Temp.?-46? ~ 8...
  6. Forrest79

    HIC TEST for Valves

    Thanks you all for the information. Stamario, We have supplied some flanges successfully which have good HIC resistance performance. For the HIC we have done test according to NACE TM0284 both standard and simulation circumstance. And the results both very good. For these products you must...
  7. Forrest79

    HIC TEST for Valves

    Friends, I am an Engineer of a flange manufacturer. now our company is studying the NACE MR 0175. We know how to do HIC and SSCC test on a flange well now. But recently our company is bidding a project, in this project the gate valves and ball valves are requested to do HIC test, I wonder how to...