  1. nationalpump

    Impeller Eye Shift - Vibration Trouble

    We balanced the impeller at operating speed. I guess I am not clear on what you are refering to when you suggest checking the balance in a "pan like manner". Are you suggesting static balancing? Thanks! Adam
  2. nationalpump

    Impeller Eye Shift - Vibration Trouble

    The impeller was dynamically balanced & installed. Post balancing the vibration remained. Any other thoughts or experiences? Thanks all. Adam
  3. nationalpump

    Impeller Eye Shift - Vibration Trouble

    It is worth mentioning that the pump is operating appropriately on the pump curve. Adam
  4. nationalpump

    Impeller Eye Shift - Vibration Trouble

    Please note that we have balanced the impeller and reinstalled it with no change in vibration. The impeller has also been ground true to the 13.87" diameter. Adam
  5. nationalpump

    Impeller Eye Shift - Vibration Trouble

    Ladies and Gents, We are investigating the cause of vibration during the operation of a cantilever pump. It should be noted that the pump has vibrated ever since the impeller was changed some months ago. We have found that the center of the impeller eye is NOT the center of the impeller...
  6. nationalpump

    Split Case Pump Cavitation - Trouble Shooting

    We have a split case pump in for repair and there is excessive cavitation damage to one side of the casing around the wear ring fit. The impeller vanes on both sides of the impeller have 1" diameter holes at suction. There is relatively no damage to the discharge portion of the casing nor the...
  7. nationalpump

    Material of Construction (500ppm Chlorides)

    Thanks for all of the information. I appreciate the feedback. Adam Nemastil
  8. nationalpump

    Material of Construction (500ppm Chlorides)

    Thanks but I am not interested in sifting.
  9. nationalpump

    Bypassing a Lot to Move a Little

    Assuming this is water service and the pump runs constantly and the right controls are installed (i.e. valving etc.) would this set-up be a problem? As long as there is enough head right?
  10. nationalpump

    Material of Construction (500ppm Chlorides)

    Thanks a ton. This is very useful info. Sometimes Google can be a real chore if you catch my drift. Thanks.
  11. nationalpump

    Material of Construction (500ppm Chlorides)

    You are correct. I guess what I would really like is a reference source so that, when I do have the data needed, I will be able to make the proper decision. Any suggestions?
  12. nationalpump

    Material of Construction (500ppm Chlorides)

    I am looking for some direction on the material of construction for pumping a fluid with 500ppm chlorides. (45-50 GPM). I do not have a temperature, which affects the considerations. Is there any reference material anyone can direct me towards? I am pretty sure that 316SS is not the correct...
  13. nationalpump

    NPSH Margin in Vertical Turbine Pumps

    As was stated by Artisi and BigInch these pumps are not the correct selection for the application regardless if they meet the NPSHr. Pumps are designed to run at BEP...not 140% BEP...where problems can be expected. So if you speed the pumps up you will still be damaging the pumps and reducing...
  14. nationalpump

    steam jacketing pump vendors

    The following two links are for steam jacketed API 610 OH2 style pumps. http://www.durapump.com/dura_api_610_pumps.html http://www.dickow.com/index.htm Dura Pump and Dickow Pumps. I hope this helps. Good Luck.
  15. nationalpump

    Sizing New Sump Pump for Existing Drainage Netwrok

    I would be interested to know whether or not you could have a Pitbull assembled in such a way that it would fit your application. The intake clearence dimension is probably recommended so that the intake does not get plugged by any solids you may have in your sump system. If you have any...
  16. nationalpump

    Pumps in Series - Total Dynamic Head Question

    What is the output (in feet of head) of the first pump? Are you using this value in your calculations? Are you also using absolute barometric pressure to calculate NPSHa? Adam
  17. nationalpump

    Sizing New Sump Pump for Existing Drainage Netwrok

    Hello, The problem you are facing may be able to be solved by an air operated submersible. The "Chicago Industrial Pump Company" produces the PITBULL pump line which should work in your situation. You would need to size the pump to operate slightly above the maximum header pressure which...
  18. nationalpump

    steam jacketing pump vendors

    The inside sales engineers at www.nationalpump.com will be able to assist you in the selection and sourcing of the pumps you are looking to purchase. You will be able to get in touch with one of the sales reps through the website. I hope this helps.