Dear all,
I have a question about a qualification of a PQR.
The thickness of the coupon is 48 mm, material is P No3. Our supplier had PWHTed at 610ºC for 1 hour and 30 min instead of 1 hour and 55 min (required for that thickness as per ASME VIII)a second cycle plus 6 hours. The mechanical test...