I appreciate all of your feed back. Still awaiting Design Eng response from ABSA. I would check appendix 22 and part UF. Unfortunately our shop is not qualified for Div 2.
Thanks for the help.
I got a request for quotation for a Pressure Vessel. The design pressure is 5000 psi and required for Lethal service. I reviewed the ABSA website and found that ASME section VIII Div I is normally up to 3000 psi. Also found statement in ASME section VIII Div I U-1(d) (Introduction), applicable...