Hi Hokie thanks again,
You have cleared most of my doubts. Actually I agreed with your advise as stated in item 2. It is a combination of poor workmanship esp. on the placement of top reinforcement and the design calculation with minimum thickness. Bytheway do you have any idea on the pattern...
Thank you Hokkie, Please find some replies to your questions. The thickness of slab is ranging from 125mm to 150mm and it is designed as one way slab. It is formed in a conventionally method using formwork and props. All the beams are R.C and the primary beams size is 450mm x 750mm spanning max...