Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. seasar

    Forcemain sewer pipe mystery?

    Since this is a forcemain sewer line isn't it likely that sewer gas is being generated by the effluent as it rots? I know the pH changes substantially from the pumping station to the point of discharge...the constiuents of the effluent would certainly harbor some biological growth. That being...
  2. seasar

    Forcemain sewer pipe mystery?

    bimr...thanks for the response. The attachment was very interesting. Increasing the velocity isn't a simple option as 1) The continuous rate of generation of effluent isn't high enough 2) If the flow were changed to intermittent with starting velocities >3.5 ft/sec the pumping station would...
  3. seasar

    Forcemain sewer pipe mystery?

    All, I have a problem I hope you can help me with...a forcemain sewer pipe that pumps effluent through a 25.4" ID pipe at 1,000 to 2,000 gpm, 30,000 ft away, elevation change from the pumping station to the open tank discharge point of +240 ft. There are a dozen air relief/vacuum breakers...
  4. seasar

    Lost hot tap coupon in a pipe

    2 3/8" Cookie...10" line...sched 40. Velocity in the line doesn't exceed 3 fps. My rule of thumb is that the velocity required to lift an object in a situation like this must be greater than the free fall velocity it would experience in a stagnant line.
  5. seasar

    Lost hot tap coupon in a pipe

    As an update...this is 32% propylene glycol at 30F.
  6. seasar

    Lost hot tap coupon in a pipe

    Had a bit of an oops moment earlier when contractor were performing a hot tap on a glycol line in that the pilot bit broke off and the coupon dropped into the pipe. The next thing the pipe does is run 50 ft up. Are there any rules of thumb for velocity required to carry an object through that...
  7. seasar

    Advice on how to move PSV discharge piping with PSV in service

    It's something they'll have when I'm done, that's for certain.
  8. seasar

    Advice on how to move PSV discharge piping with PSV in service

    StoneCold....thanks, this would work for some of them, most are too close together coming out of the selector valve though.
  9. seasar

    Advice on how to move PSV discharge piping with PSV in service

    Duwe6....Thanks! I hadn't thought of doing the work partially in full level A suits.
  10. seasar

    Advice on how to move PSV discharge piping with PSV in service

    The dual PRVS (of which one is in service and the other is in standby...done so that either one can be recertified without takind down the affected equipment) tee back into a common discharge pipe. Some of these discharge pipes are within 15 ft of the ground (not compliant with ASHRAE 15 which...
  11. seasar

    Advice on how to move PSV discharge piping with PSV in service

    Its the US...the relief valves themselves are configured in a dual arrangement with a selector valve. They share a common discharge pipe and that is the issue. The reliefs are recertified every 5 years.
  12. seasar

    Advice on how to move PSV discharge piping with PSV in service

    Howdy...I have a facility which has ammonia relief valve discharge piping that is well under 15 ft from the ground. The protected equipment includes, among other things, the primary suction header for the facility and it can't be easily taken out of service (has never been in 30 years). I'm...
  13. seasar

    Uncovered buried pipe support during pressure test? Guidelines?

    Hello all, I'm about to bid work involving installing new underground natural gas pipe with a requisite pressure test...I'm trying to find a reference for how to support pipe during the pressure test that is uncovered. I know there are guidelines for how many feet of what diameter can be...
  14. seasar

    Distillation engineering

    Can someone point me in the direction of how to learn more about the science and engineering of distillation? I am a process engineer with responsibility for, among things, an alcohol distillation unit with a molecular sieve dehydrator. I'd like to learn more about the engineering that governs...
  15. seasar

    Ethyl Alcohol Saturated Liquid/Gas Properties

    Thank you! These are exactly what I was looking for!
  16. seasar

    Ethyl Alcohol Saturated Liquid/Gas Properties

    Can someone point me in the direction of the properties of saturated ethyl alcohol at different temps and pressures? Density & enthalpy would be great...superheated properties would be really really appreciated. Something like what NIST offers for certain fluids...
  17. seasar

    Ethanol recovery by Distillation

    Can someone point me in the direction of how to learn more about the science of engineering of distillation? I am a process engineer with responsibility for, among things, an alcohol distillation unit with a molecular sieve dehydrator that I've inherited. I'd like to learn more about how and...
  18. seasar

    Automated Compressed Air Leak Detection? (via instrumentation)

    A few weeks ago I had a voicemail from a cold-calling salesman regarding some equipment that if mounted in a compressed air header could be used to determine the magnitude of and when system leaks occur. I dismissed it without retaining any contact info as I thought it to be very likely a waste...
  19. seasar

    Leak from low pressure to high pressure???

    I have a process in which liquified CO2 with less than 1ppm of entrained O2 stored at 240 psig on one side of a ball valve with air at a few psig on the other appears to not only leak CO2 through the valve (small amounts) but the CO2 appears to absorb O2 through it as well (very small amounts...
  20. seasar

    Techniques for measuring pipeline surge/shock/hammer?

    Instead of doing it myself, with equipment and expertise I don't have, are their experts in this field that could be hired? Can someone point me in the right direction regarding them? The original company that did the design did a surge analysis and it may still be fine. This company's...
Back
Top