In API 6A Slab Gate Valves 'O' Ring seals are generally used upto 5000 psi as secondary seals with primary metal to metal seal. However, it is general practice to limit the bare 'O' Ring seals upto 2000 psi and beyond this and upto 5000 psi, it is common to use 'O'Rings with metal back up rings...