To anyone who can help.
I am looking for good author/text/book recommendation on the following:
Meshing in ANSYS CFX 12.0 or later
BladeGen in ANSYS CFX 12.0 or later
Vista CPD in ANSYS CFX 12.0 or later
Centrifugal Impeller Design - Specifically Francis Vane Blade and Impeller Design (not for...
Has anyone heard of or seen the phenomena where the base circle diameter of an involute helical gear is larger than the root diameter??? I am running into this an can't determine if it is a problem or not.
See attached screenshot of the beginning of a model for a helical gear in PRO-E. Shown...
many know that other customers and vendors use different CAD software. and we know that we can import there files into our software programs. for example IGES or STEP files. to do this we import the file into a new part model. once we do this we will see only one feature in the model tree, an...
From personal experience of slow running pro-e, framing screen, slow loading, etc. etc.. It was because my computer didn't have a fast enough processor or insufficient memory. After working with Pro-E for a year with this same computer, my employer purchased me a brand new Dell, since then...
I have not had any experience or training using filters or relations in detailed drawings in Pro-E. I was wondering if anyone knows how to or if it is even possible to write and IF THEN statement that would change the part number in a drawing, as well as change the name of the part(description)...
I have not had any experience or training using filters or relations in detailed drawings in Pro-E. I was wondering if anyone knows how to or if it is even possible to write and IF THEN statement that would change the part number in a drawing, as well as change the name of the part(description)...
so far I have come up with these gage wires for these lengths:
0' to 5' = #8
5' to 8' = #6
8' to 12' = #4
12' to 16' = #2
16' to 20' = #2
20' to 25' = #1
Now this is for copper positive lead wire for a 24 vdc starter motor, 140 amp draw, and a voltage drop of less than .500 volts over these...
No, this is not a college homework problem. I work for a fire truck pump company, we have a 12 vdc and 24 vdc version starter motor, which incorporate a solenoid. These motors are engaged by pulling a valve handle to the open position which connects the circuit to ground, engaging the motor...
I have a 24 vdc motor, that will be running at 140 amps. I need less than 1/2 volt of voltage drop over the length of the wire. I have lengths of copper wire for the positive lead as follows:
0' to 5'; 5' to 8'; 8' to 12'; 12' to 16'; 16' to 20'; and 20' to 25'. What is the best way to...