  1. philharm

    Conflicting problem...galvanic corrosion and floating metal!

    Very benign. Say 60%RH usually, 110F max. very infrequent exposure to humidity by the ocean, thus low salt level. Thanks in advance for anyone's input!
  2. philharm

    Conflicting problem...galvanic corrosion and floating metal!

    Thanks for your response! Unfortunately painting the cathode is not an option. The operation environment is not really a concern here.....the problem is the very strict contractual requirement from our customers. We have strict requirement that no ungrounded metal is allowed, and all...
  3. philharm

    Conflicting problem...galvanic corrosion and floating metal!

    I am running into a conflicting problem. I am trying to bolt down a small aluminum casing on a large nickel plate....due to the fact that we need to ground this aluminum casing to the Ni plate. In order to accomplish that, I need to rid of the anodized surface of the Al.... now I got a new...