Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. ketaciturn

    Panasonic Servo Driver Setting...

    In my application, i'm trying to move a number of cups from point A to Point B with several indexes. And the distance between indexes should be exactly the same, so the servo driver is used at position control mode. Since the cups is filled with water, and when the speed of the whole process...
  2. ketaciturn

    Panasonic Servo Driver Setting...

    Good day Everyone! I've a question regarding Panasonic AC servo motor 750W, with its driver MSDA083A1A, and I'm using it to run under position control mode. But i need to use the acceleration and deceleration time in my application... So, how to set the driver so that it runs under position...
  3. ketaciturn

    Touch Panel Problem.

    Hi guys! I have a Pro-face GP57J-SC11 touch panel, connected to a Omron C200HG-CPU33 PLC. The problem that i faced is that the Pro-face can't redirect me to other page, and at the bottom right corner of the touch panel, there are two lines of message, that is: C:0110 D:0100 ms and the digit...
  4. ketaciturn

    Proface related problem

    Hi guys! I have a Pro-face GP57J-SC11 touch panel, connected to a Omron C200HG-CPU33 PLC. The problem that i faced is that the Pro-face can't redirect me to other page, and at the bottom right corner of the touch panel, there are two lines of message, that is: C:0110 D:0100 ms and the digit...
  5. ketaciturn

    2 phase question

    jbartos, yupp, u r right. Eventhough i got what u mean already, thanks for further elaborating it!! Thanks alot for ur kindness and effort!!
  6. ketaciturn

    2 phase question

    sorry, i got what u mean already... just forget about the previous post.......sorry..
  7. ketaciturn

    2 phase question

    jbartos, "since it is not true single phase power supply that may need one fuse or breaker in one wire only." can u please elaborate on this.....thanks. How if i just use 1 breaker for the two wire R,S before and after the stabilizer??
  8. ketaciturn

    2 phase question

    i think the configuration should be ok. thanks guys...
  9. ketaciturn

    2 phase question

    u r right Bang, this is what my question is actually... For a 3 phase 200V supply (let say R,S,T), the voltage across any 2 lines (R,S or S,T or T,R) is 200V right? Instead of using a single phase 200V power source, can i use the "2 phase" 200V(R,S)(which is tapped from 3phase 200V)...
  10. ketaciturn

    2 phase question

    sorry for confusing u guys, i think i better clearify something... the PLC is using 100V single phase as input. and the stabilizer is using 200V single phase as input, and its output is 100V single phase. The power source that i have is a 200V 3 phase. So, what i meant was, is it possible to...
  11. ketaciturn

    2 phase question

    Maybe this question is a little bit too basic for u guys, but please help this poor little kid---me!! :) What's the diffrent between 2 phase 200VAC and single phase 200VAC? If i have a voltage stabilizer which requires 200VAC single phase supply, can i supply it with 200VAC 2 phase supply? The...

Part and Inventory Search