Search results for query: *

  1. elquesifilma

    Chemical Reaction from CO2/ Water/H2S, H2 permeating damaging diaphram when calibrating wedge meter

    Dear Fellow Eng-tips technical experts, I am trying to figure out what chemical reaction occers that frees up Hydrogen molecules in the following process I have a wedge meter transmitter that we are experience hydrogen premeation from our process of CO2 fluid which contains H2S and produced...
  2. elquesifilma

    Predicting H2S ppm on oil/water by knowing H2S in gas

    All, I am trying to predict the H2S content of produced water and oil at atmospheric conditions (tanks) by knowing H2S content of gas phase from my separator operating at 100 psig and 80F. This would help determine whether I need to specify NACE compliant materials. Oil API gravity 40 SG...
  3. elquesifilma

    Convert PSV capacity from scfm air to scfm of gas

    I have a PSV valve report that gives me the calculated capacity of the PSV in scfm of air. I need to know what the relief capacity is for another gas composition help is greatly appreciated.
  4. elquesifilma

    Recommended safety devices wellhead flowlines

    We currently have production wells with ESP (Electrical Submersible Pumps). What are the typical safety devices to protect the flowline from rupturing form overpressure? Our flowlines are polyethylene SDR 7 which are rated at 133 psi for Crude service. The flowlines are tied into 3 phase...
  5. elquesifilma

    Calculate volume stock tank vapors to size Vapor Recovery Unit

    I need to calculate volume stock tank vapors (scfd) to size Vapor Recovery Unit. The total volume needs to account for flash losses, working and breathing losses. The facility currently has a 3-phase production separator which operates at normal operation pressure 50 psi ( min 35 psi, max 70...
  6. elquesifilma

    Stainless steel pressure rating 3 inch operating 2100 psi

    Better question. What is the pressure rating for 3 inch stainless steel 316, schedule 40 and schedule 80? for a produced water application. Thanks
  7. elquesifilma

    Stainless steel pressure rating 3 inch operating 2100 psi

    Looking to install 3 inch stainless steel pipe. The service is produced water. My pressure is 2100 psig. If i were using carbon steel i would buy 3 inch schedule 40 , Grade B (35000 yield strength) which for B31.4 is good for 2390 psig. For stainless steel pipe does B31.4 apply? what yield...
  8. elquesifilma

    Pump efficiency operating cost evaluation

    Thank you BigInch. Allthough if i have a 100 HP motor on the skid, but my curve shows the operating point only using 75 HP, should i run the numbers with 75 HP? What am i consuming when i run at design point, the full skid 100HP or just what the rated 75 HP?
  9. elquesifilma

    Pump efficiency operating cost evaluation

    Hello All, I want to evaluate 2 pumps for the following application. S.G fluid: 1.05 Flow: 350 gpm P: 600 ft head I found 2 pump curves that work for my application. -Curve 1: shows the design point requiring 75 HP with a pump efficiency of 80%. Pump would require 100HP motor to cover the...
  10. elquesifilma

    API gravity question

    My understanding is that API gravity of oil is a density measure at 60 F. Would my API gravity of my Oil change at 1000 psi if i take it to a separator at 100 psi. I am assuming i will flash some of the light hydrocarbons (C1,C2) so my crude oil composition now changes. Would the API gravity...
  11. elquesifilma

    oil cut, GOR question

    Thank you all
  12. elquesifilma

    oil cut, GOR question

    What does it mean when i am told a well produces 1000 barrels of total fluid with a GOR of 500 scf/bbl and 50% oil cut? with a wellhead pressure of 2000 psi at primary production? How much oil, produces water and gas will i be producing? does this mean 500 bbls of oil, and 500 bbls of water...
  13. elquesifilma

    How to size a Vapor Recovery Unit

    I need help in sizing a Vapor Recovery Unit. Basically i need to calculate total release volume to size the compressor and scrubber. How can i estimate the total losses (flashing/working and breathing losses)? do i need to calculate all 3 to size a VRU for that capacity? We have a...
  14. elquesifilma

    insulating polyethylene pipe for freezing

    More Information: purpuse of the line to transfer fresh water SG 1. Freezing point 32F. Temperature of the water i would say 60 F, and constant flow. Allthough at upsets you can have no flow, where freezing is of concern. Its in new mexico where temperatures in winter go to 10 F. The field is...
  15. elquesifilma

    insulating polyethylene pipe for freezing

    We currently have a 4000 ft of 10 inch SDR 11 polyethylene pipe which we are planning on laying below ground for fresh water transfer (lowest temp ever recorded 5 F, normal low temp is 20 F). The reason for burying the pipe is that we are concerned with freezing. The problem we have is that the...
  16. elquesifilma

    Tank Nozzle sizes and orientation (height)

    Good Day, I am designing a settling tank system, with 3 tanks in series, they are API std tanks each 1500 bbls, with 26" diameter and 16" height. They will be settling any particles from water source. What are recommended height of inlet/overflows/outlet nozzles? , as well as drains?. I am...
  17. elquesifilma

    line and pump hydraulics

    BigInch, Artisi and katmar, thanks for all your responses and recommendations. I will analyze and think about the system further, and get back to you guys if i have any other concerns or to let you know how it all works out Thanks!
  18. elquesifilma

    line and pump hydraulics

    Thanks for the responses. This problem is not a homework problem, it is a project i should be implementing soon. I actually have been told we will be flowing about 40,000 bwpd thru the line, so my velocity will be about 6.15 fps and required pressure of 87.5 for the pumps to get from A to B. I...
  19. elquesifilma

    line and pump hydraulics

    I need to move 60,000 barrels of water from point A (elevation 0 ft) to point B(elevation 100 ft). The distance is 5000 ft. The line is fixed at 8.8 inch internal diameter. A tank at point A feeds my pump which will pump the liquid to a tank at point B. Using Hazen-Williams equation i calculate...
  20. elquesifilma

    Flow Control, piping arrangements booster pump to 2 separate systems.

    wow, thank you all for your excellent responses. I will be more specific next time. I am thinking on having a common discharge header with a valve to isolate the two systems, as described by BigInch. This should give me flexibility, if anything changes in the future, its basically 2 systems i am...