Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Qwikone

    Ridge beam undersized--any ideas on how to reinforce it now that its in place?

    I agree there are many "issues" with this ---I am meeting the folks on site tomorrow to get the real scoop. The dimensions I have been given (and pics) show a difference in depth of the 2x12's. The problem is also with the dimensions of the porch. I am getting the impression after speaking with...
  2. Qwikone

    Ridge beam undersized--any ideas on how to reinforce it now that its in place?

    KootK- The County wants a sealed letter, and I'm not concerned with the 6% either, just looking for a solution that would put it back in the green. I may bolt/screw something to the bottom...... XR250- Just lazy I guess.......or old. LOL
  3. Qwikone

    Ridge beam undersized--any ideas on how to reinforce it now that its in place?

    Members- I was called to look at a 2-2x12 ridge beam spanning 11'9" on a mostly finished porch roof yesterday afternoon. The rafters are 2x8, and the roof pitch is 5:12. The issue is that the inspector noticed a difference in depth of the 2x12's, one is 11-1/2" and the other about 11". He said...
  4. Qwikone

    Placing column footing next to existing wall--foundation

    Thanks for all the great replies!! I am proceeding with underpinning the existing wall (light loads--non-bearing walls above it) placing the column footing below and underpinning a portion of the existing footing. This gets me the minimum offset of the column, with minimal impact to the existing...
  5. Qwikone

    Placing column footing next to existing wall--foundation

    Mike- Thank you for such a quick response!! That will work nicely...... Qwik
  6. Qwikone

    Placing column footing next to existing wall--foundation

    I have an existing wall with concrete footer/foundation at 30" deep. I need to place a column supporting a girder truss adjacent to the existing foundation, the problem is that I need to get the column as close to the wall (6"-12") as possible. The existing footer is 24" wide with 8" block in...
  7. Qwikone

    Drift or Horizontal deflection limits of rigid frames

    Update-- The Base accepted the H/250 for this case. Thank you for all your help and suggestions!! Qwik
  8. Qwikone

    Drift or Horizontal deflection limits of rigid frames

    Just noticed....its standing seam, not seamless.....
  9. Qwikone

    Drift or Horizontal deflection limits of rigid frames

    Thanks guys for all the great input. Some additional details I left out. StructSU10 is close--this will be a military structure. It is actually an open "sun-shield" with no siding. Basically a steel frame 24' high open sides and a 4/12 pitch standing seamless metal roof. We are submitting a...
  10. Qwikone

    Drift or Horizontal deflection limits of rigid frames

    Folks- Hopefully you all can settle a disagreement. The subject is a steel rigid frame--roof only, and the discussion is whether the drift limit is H/60, or as the Designer quotes from the UFC-3-301-01 Structural Engineering Chapter 2 Modifications to IBC, 2-1.2.1 1604.3 Serviceability...